The Exit Delay must not exceed 120 seconds.The Entry Delay must not exceed 120 seconds.The control panel must be in the attack resistant enclosure (DSC Model CMC-1.Grade B Central Station and Police Connect The entire manual should be carefully read. WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The control panel must be in the attack-resistant enclosure (DSC Model CMC-1.The digital communicator must be enabled.(AMSECO MBL10B with model AB-12 bell housing). The installation must have a bell which is UL Listed for mercantile local alarms.Promise detection time must be 6 minutes. WAN/Internet to the SG System III receiver. The Sur-Gard MLR-IP receiver or the TL200/250 which communicates over LAN/ The installation must use T-Link module which communicates over LAN/WAN to Grade AA Central Station and Police Connect (Standard or Encrypted Line The installation requirements listed below must be met for the following UL Listed Commercial and Residential Installations